DigiPara Liftdesigner LDX API
Loading...
Searching...
No Matches
Change properties of a panel

API method: ILDXCarFloorPanel5.Mode

Treename: Shaft0.Car.Design.Floor.Panels.PanelRow3.Panel1.

 ' from Samples/Src/LDXAPIExamples/Example_LDXCarFloor.vb

    <APIHelpAttribute(APIHelpModes.FireCalcModel Or APIHelpModes.LoadLD3File, {APIHelpModes.InputParaLDXDoc}, "Shaft0.Car.Design.Floor.Panels.PanelRow3.Panel1.", "LDXCarFloorPanel~Mode", "Change properties of a panel")>
    Public Shared Sub ChangePropertiesOfAPanel(ByRef ldxDocument As DigiPara.LDX.LDXDocument)

        If ldxDocument.GetLDXObject("Shaft0.Car.Design.Floor.Panels.PanelRow3.Panel1.") Is Nothing Then
            MsgBox("Desired car floor panel not found! Please reload the relevant .ld3 file.")
            Exit Sub
        End If

        With DirectCast(ldxDocument.GetLDXObject("Shaft0.Car.Design.Floor.Panels.PanelRow3.Panel1.").LDXType, DigiPara.LDX.LDXCarFloorPanel)
            ' Panel properties are independent of other panels within the column
            .Mode = .Mode Or DigiPara.LDX.CarFloorPanelModes.cfpDifferentType
            ' Change the clearance
            .CarFloorPanelTab.SetValue("CFP_USER_PG_50", 35)
        End With

    End Sub