DigiPara Liftdesigner LDX API
|
API method: ILDXLadder5.Mode
Treename: Shaft0.Ladder.
2 code examples follow.
' from Samples/Src/LDXAPIExamples/Example_LDXLadder.vb
<APIHelpAttribute(APIHelpModes.FireCalcModel Or APIHelpModes.LoadLD3File, {APIHelpModes.InputParaLDXDoc}, "Shaft0.Ladder.", "LDXLadder~Mode", "Fix ladder at separator beam")>
Public Shared Sub ChangeMode(ByRef ldxDocument As DigiPara.LDX.LDXDocument)
If ldxDocument.GetObject("Shaft0.Ladder.") Is Nothing Then
MsgBox("Ladder not found!")
Exit Sub
End If
Dim shaft As DigiPara.LDX.LDXShaft = ldxDocument.Shafts(0)
With shaft.Ladder
' change to ladder with all the new features
If .Comp.RID64 <> 6 Then
.Comp.ChangePartRID64(6, 0)
End If
.Comp.Wall = shaft.CWConsole.Comp.Wall
If (.Mode And DigiPara.LDX.LadderModes.lmFixedAtOwnBeam) = DigiPara.LDX.LadderModes.lmFixedAtOwnBeam Then
' enable fixing at existing separator beams
.LadderTab.SetValue("LT_DESC", "Fix at existing beams from rail bracket list")
.Mode = (.Mode And Not DigiPara.LDX.LadderModes.lmFixedAtOwnBeam) Or DigiPara.LDX.LadderModes.lmFixAtSeparatorBeam
' enable separator beams
With shaft.Console(.Comp.Wall)?.RailBrackets
.RBL_MODE = .RBL_MODE Or DigiPara.LDX.RailBracketsModes.rbmSeparatorBeam Or DigiPara.LDX.RailBracketsModes.rbmFixTypeSteel
End With
ElseIf (.Mode And DigiPara.LDX.LadderModes.lmFixAtSeparatorBeam) = DigiPara.LDX.LadderModes.lmFixAtSeparatorBeam Then
' disable fixing at separator beams
.LadderTab.SetValue("LT_DESC", "Fixed directly at wall")
.Mode = .Mode And Not DigiPara.LDX.LadderModes.lmFixedAtOwnBeam And Not DigiPara.LDX.LadderModes.lmFixAtSeparatorBeam
' disable separator beams
With shaft.Console(.Comp.Wall)?.RailBrackets
.RBL_MODE = .RBL_MODE And Not DigiPara.LDX.RailBracketsModes.rbmSeparatorBeam
End With
Else ' no separator beam set
' enable fixing at own separator beam
.LadderTab.SetValue("LT_DESC", "Fix at own separator beams")
.Mode = .Mode Or DigiPara.LDX.LadderModes.lmFixedAtOwnBeam
' disable separator beams
With shaft.Console(.Comp.Wall)?.RailBrackets
.RBL_MODE = .RBL_MODE And Not DigiPara.LDX.RailBracketsModes.rbmSeparatorBeam
End With
End If
End With
EnsureLadderViews(ldxDocument)
End Sub
' from Samples/Src/LDXAPIExamples/Example_LDXLadder.vb
<APIHelpAttribute(APIHelpModes.FireCalcModel Or APIHelpModes.LoadLD3File, {APIHelpModes.InputParaLDXDoc}, "Shaft0.Ladder.", "LDXLadder~Mode", "Build custom ladder")>
Public Shared Sub SetupCustomSteps(ByRef ldxDocument As DigiPara.LDX.LDXDocument)
If ldxDocument.GetObject("Shaft0.Ladder.") Is Nothing Then
MsgBox("Ladder not found!")
Exit Sub
End If
Dim shaft As DigiPara.LDX.LDXShaft = ldxDocument.Shafts(0)
With shaft.Ladder
If .Comp.RID64 <> 1 Then
' back to old standard ladder
.Comp.ChangePartRID64(1, 0)
Else
With .Comp
' clean slate
.ChangePartRID64(2, 0)
While .Profiles.Count > 0
.Profiles.RemoveAt(0)
End While
' make side shafts
For i As Integer = -1 To 1 Step 2
With .Profiles.Add()
.TYP = ProfileType.prtQ
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtL, Integer), "30")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtH, Integer), "2*[8] + [10]") ' STEP_START + STEP_TOTAL
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtB, Integer), "80")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionX, Integer), $"{i * 0.5}*[0]") ' B
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionY, Integer), "-0.5*[98]") ' PDY
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionZ, Integer), "0.5*[96]") ' PDZ
End With
Next
' make rung; rungs are replicated at appropriate z positions from PGT_RID -1
With .Profiles.Add()
.PGT_RID = -1
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtL, Integer), "[0]") 'B
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtH, Integer), "20")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtB, Integer), "80")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionY, Integer), "-0.5*[98]") ' PDY
End With
' make fixings; they are defined by PGT_RID -2 to -4.
For i As Integer = 1 To 3
For j As Integer = -1 To 1 Step 2
With .Profiles.Add()
.TYP = ProfileType.prtQ
.PGT_RID = -1 - i
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtL, Integer), "20")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtH, Integer), "100")
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtB, Integer), "[2]") ' T, distance to wall
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionX, Integer), $"{j * 20} + {j * 0.5}*[0]") ' B
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionY, Integer), "-0.5*[98]") ' PDY
.SetEquation(DirectCast(DigiPara.LDX.ProfileEquationType.peqtLocalPositionZ, Integer), $"0.5*[96] + [{i + 10}]") ' PDZ, FIXING_i_HEIGHT
End With
Next
Next
End With
' Activate custom geometry by profile group with fixings activated
.Mode = .Mode Or LadderModes.lmDoNotDrawDefault Or LadderModes.lmCustomStepsSupport Or LadderModes.lmFixedAtOwnBeam
' we don't activate the separator beams themselves, though, that could happen over .SeparatorBeam
' Set steps
.STEP_COUNT = 5
.STEP_DIST = 300
.STEP_START = 150
' set width
.B = 400
' activate only two of the fixings
.FIXING_COUNT = 2
' position fixings
.FIXING_HEIGHT(1) = 10 ' Bottom fixing should get index 1
.FIXING_HEIGHT(0) = .FIXING_HEIGHT(1) + .STEP_DIST * 4 ' top fixing gets index 0 so it is activated first
.FIXING_HEIGHT(2) = .FIXING_HEIGHT(1) + .STEP_DIST * 2 ' middle fixing in case user activates it
' set distance to wall
.T = 140
.LadderTab.SetValue("LT_DESC", "Ladder built from custom profile group")
End If
End With
EnsureLadderViews(ldxDocument)
End Sub