DigiPara Liftdesigner LDX API
Loading...
Searching...
No Matches
Synchronize anchor rail length

API method: ILDXObject5.SendChangeNotification

Treename: Shaft0.CW.BracketList.Bracket0.AnchorRail0.

 ' from Samples/Src/LDXAPIExamples/Example_LDXAnchorRail.vb

    <APIHelpAttribute(APIHelpModes.FireCalcModel Or APIHelpModes.LoadLD3File, {APIHelpModes.InputParaLDXDoc}, "Shaft0.CW.BracketList.Bracket0.AnchorRail0.", "LDXObject~SendChangeNotification", "Synchronize anchor rail length")>
 Public Shared Sub SynchronizeAnchorRailLength(ByRef ldxDocument As DigiPara.LDX.LDXDocument)

     If ldxDocument.GetLDXObject("Shaft0.CW.BracketList.Bracket0.AnchorRail0.") Is Nothing Then
         MsgBox("Anchor rails not found!")
         Exit Sub
     End If

     With ldxDocument.Shafts(0).CWConsole.Console.RailBrackets(0).GetAnchorRail(0)
         .Length = 1000
         If MsgBox("Do you want to change the bottom anchor rail length only? If not all anchor rail lengths will be changed.", MsgBoxStyle.YesNo) = MsgBoxResult.No Then
             .Object.SendChangeNotification("", "AR_MODE")
         End If
     End With

 End Sub