DigiPara Liftdesigner LDX API
|
API method: ILDXRoof5.Thickness
Treename: Shaft0.Roof.
' from Samples/Src/LDXAPIExamples/Example_LDXRoof.vb
<APIHelpAttribute(APIHelpModes.FireCalcModel Or APIHelpModes.LoadLD3File, {APIHelpModes.InputParaLDXDoc}, "Shaft0.Roof.", "LDXRoof~Thickness", "Change Total Roof Thickness")>
Public Shared Sub ChangeRoofThickness(ByRef ldxDocument As DigiPara.LDX.LDXDocument)
Dim roof As DigiPara.LDX.LDXRoof = ldxDocument.Shaft.Room.Roof
ActivateFrontRearOnly(roof)
Dim roofFaceFront = roof.GetFace(DigiPara.LDX.WallType.wtFront)
Dim roofFaceRear = roof.GetFace(DigiPara.LDX.WallType.wtRear)
' disable individual thickness
roofFaceRear.RoofFaceMode = roofFaceRear.RoofFaceMode And Not DigiPara.LDX.RoofFaceModes.rfmManualThickness
roofFaceFront.RoofFaceMode = roofFaceFront.RoofFaceMode And Not DigiPara.LDX.RoofFaceModes.rfmManualThickness
' change roof thickness
If roof.Thickness < 100 Then
roof.Thickness = 300
Else
roof.Thickness = 50
End If
End Sub